The Disable-NetAdapterRsc cmdlet disables receive segment coalescing (RSC) on a network adapter.
If IPv4 or IPv6 are not specified, then both are disabled.
RSC takes multiple packets that were received within the same interrupt period and combines the packets into a single large package to be processed by the network stack.
This reduces the processing overhead for incoming packets and reduces the number of processor cycles that are used, leading to better scalability.
Examples
Example 1: Disable RSC for IPv6 on the specified network adapter
This example disables RSC for IPv6 on the network adapter named MyAdapter and restarts the network adapter.
Parameters
-AsJob
Runs the cmdlet as a background job.
Use this parameter to run commands that take a long time to complete.
The cmdlet immediately returns an object that represents the job and then displays the command prompt.
You can continue to work in the session while the job completes.
To manage the job, use the *-Job cmdlets.
To get the job results, use the Receive-Job cmdlet.
For more information about Windows PowerShell® background jobs, see about_Jobs.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-CimSession
Runs the cmdlet in a remote session or on a remote computer.
Enter a computer name or a session object, such as the output of a New-CimSession or Get-CimSession cmdlet.
The default is the current session on the local computer.
Parameter properties
Type:
CimSession[]
Default value:
None
Supports wildcards:
False
DontShow:
False
Aliases:
Session
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-Confirm
Prompts you for confirmation before running the cmdlet.
Parameter properties
Type:
SwitchParameter
Default value:
False
Supports wildcards:
False
DontShow:
False
Aliases:
cf
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-IncludeHidden
Indicates that the cmdlet includes both visible and hidden network adapters in the operation.
By default only visible network adapters are included.
If a wildcard character is used in identifying a network adapter and this parameter has been specified, then the wildcard string is matched against both hidden and visible network adapters.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
ByName
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
ByInstanceID
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-InputObject
Specifies the input to this cmdlet.
You can use this parameter, or you can pipe the input to this cmdlet.
Parameter properties
Type:
CimInstance[]
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
InputObject (cdxml)
Position:
Named
Mandatory:
True
Value from pipeline:
True
Value from pipeline by property name:
False
Value from remaining arguments:
False
-InterfaceDescription
Specifies an array of network adapter interface descriptions.
For a physical network adapter this is typically the name of the vendor of the network adapter followed by a part number and description, such as Contoso 12345 Gigabit Network Device.
Parameter properties
Type:
String[]
Default value:
None
Supports wildcards:
False
DontShow:
False
Aliases:
ifDesc, InstanceID
Parameter sets
ByInstanceID
Position:
Named
Mandatory:
True
Value from pipeline:
False
Value from pipeline by property name:
True
Value from remaining arguments:
False
-IPv4
Indicates that this cmdlet affects IPv4 traffic.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-IPv6
Indicates that this cmdlet affects IPv6 traffic.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-Name
Specifies an array of network adapter names.
Parameter properties
Type:
String[]
Default value:
None
Supports wildcards:
False
DontShow:
False
Aliases:
ifAlias, InterfaceAlias
Parameter sets
ByName
Position:
0
Mandatory:
True
Value from pipeline:
False
Value from pipeline by property name:
True
Value from remaining arguments:
False
-NoRestart
Indicates that the cmdlet does not restart the network adapter after completing the operation.
Many advanced properties require restarting the network adapter before the new settings take effect.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-PassThru
Returns an object representing the item with which you are working.
By default, this cmdlet does not generate any output.
Parameter properties
Type:
SwitchParameter
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-ThrottleLimit
Specifies the maximum number of concurrent operations that can be established to run the cmdlet.
If this parameter is omitted or a value of 0 is entered, then Windows PowerShell® calculates an optimum throttle limit for the cmdlet based on the number of CIM cmdlets that are running on the computer.
The throttle limit applies only to the current cmdlet, not to the session or to the computer.
Parameter properties
Type:
Int32
Default value:
None
Supports wildcards:
False
DontShow:
False
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
-WhatIf
Shows what would happen if the cmdlet runs.
The cmdlet is not run.
Parameter properties
Type:
SwitchParameter
Default value:
False
Supports wildcards:
False
DontShow:
False
Aliases:
wi
Parameter sets
(All)
Position:
Named
Mandatory:
False
Value from pipeline:
False
Value from pipeline by property name:
False
Value from remaining arguments:
False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable,
-InformationAction, -InformationVariable, -OutBuffer, -OutVariable, -PipelineVariable,
-ProgressAction, -Verbose, -WarningAction, and -WarningVariable. For more information, see
about_CommonParameters.
The Microsoft.Management.Infrastructure.CimInstance object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#) provides the namespace and class name for the underlying WMI object.
The Microsoft.Management.Infrastructure.CimInstance object is a wrapper class that displays Windows Management Instrumentation (WMI) objects.
The path after the pound sign (#) provides the namespace and class name for the underlying WMI object.